Titelgrafik

starlight s sler® (black/black)
steel body with black selection panel, black optical fiber
Ref. n°: 05100062


starlight s sler® (black/transparent)
steel body with black selection panel, transparent optical fiber
Ref. n°: 05100063


starlight s sler® (grey/black)
steel body with grey selection panel, black optical fiber
Ref. n°: 05100064


starlight s sler® (grey/transparent)
steel body with grey selection panel, transparent optical fiber
Ref. n°: 05100065

   

starlight s sler® - built-in version

for a better curing result

sler® stands for „soft light energy release”, a slow decrease of light intensity at the end of the cycle. This patented mectron technology modulates and controls the temperature and shrinkage of the composite, improving its mechanical properties.

 

for flexible use

Polymerization with more than 1.400 mW/cm2. The starlight s sler® can be
easily built into a dental unit – the ergonomic handpiece can be positioned
simply in the quiver (its holder). starlight s sler® is equipped with 6 different operating modes.


Technical specifications

Size (L x Ø)
141 x 25 mm

Weight
122 g

Light source
5W LED with optical focusing

Wavelength range
440–480 nm with peak at 460 nm

Fibreglass light guide
Ø 8 mm, transparent, , can be sterilised at 135° C
Option: Ø 8 mm, black, can be sterilised at 135° C

Light intensity
Ø 8 mm light guide, transparent > 1.400 mW/cm2

Working life of LED
2.500.000 cycles, 10 seconds each

Waranty
3 years (on the device, excluding the light guide)

sler® technology


Standard program per 10 sec

standard effects
Temperature and shrinkage exhibit an inverse relation. Interrupting light exposure stops the energy supply but the curing process is ongoing.


Comparison of Standard mode (10 sec) and sler mode (9 sec max power and 2 sec constant decrease)

temperature control
Compared to a standard curing cycle, the sler® technology shows a better thermal control of the curing process. This protects against interface debonding, which may lead to marginal leakage.


Comparison of Standard mode (10 sec) and sler mode (9 sec max power and 2 sec constant decrease)

shrinkage control
The sler® technology allows the dental material to relax its shrinkage stress at the end of the curing cycle. This decreases the possibility of micro-fractures both in the composite material and in the dentine substrate.


Comparison of different materials (color A2)

mechanical strength increase
Composite materials cured with sler® technology show improved mechanical strength, which contributes to better clinical performances.


Mectron s.p.a. | T. 0039 0185 35361 | mectron@mectron.com | VAT identification number: P.IVA IT00177110996